Vue de la page 64
6-1
BARHOLE TESTING MODE
6
BARHOLE TESTING MODE
This mode is used to locate underground leaks and on
start-up will be ranged to 0-100% LEL which will
autorange to VOL gas at 100% LEL.
6.1 BARHOLE RANGES
Barhole testing will have the following ranges available:
0  100% LEL
0 100% Vol Gas
6.2 BARHOLE FEATURES
Barhole mode will have the following features:
Timed or Non-Timed Sampling
Backlight
Flashlight
Pump control
Invert Display
Six sets of barhole readings with Viewing /
Overwriting.