Heath-consultants Heath Volume Corrector (HVC) Manuel d'utilisateur Page 1

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Instruments de mesure Heath-consultants Heath Volume Corrector (HVC). Heath Consultants Heath Volume Corrector (HVC) User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 36
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Heath Volume Corrector
HVC 325 Series
Users Manual & Field Installation Guide
Heath Consultants Inc.
Houston, TX
713-844-1300
Fax: 713-844-1309
1-800-HEATH-US
www.heathus.com
Vue de la page 0
1 2 3 4 5 6 ... 35 36

Résumé du contenu

Page 1 - HVC 325 Series

Heath Volume Corrector HVC 325 Series User’s Manual & Field Installation Guide Heath Consultants Inc. Houston, TX 713-844-1300

Page 2 - 325 IS Series

10 Form “C” PCB (Optional) This is an optional feature that adds two Form “A” pulses for Corrected and two for Uncorrected. External Modem The HVC 3

Page 3 - Table of Contents

11 HVC HOST Operating Software HVC Host is the companion software interface to the HVC instrument. The application program provides for

Page 4 - HVC Features

12 Quick Start Guide Note: Click “F1” key for help on any item. 1. Install the HVC Host software from the CD software disk provided. 2. Setup

Page 5

13 Configure 1 Screen * Meter Drive (Input Scale Factor)= (X1, X5, X10, X100, X1,000, X10,000) Should correspond to the amount of uncorrected ga

Page 6

14 * Uncorrected Volume/ Leading blanks or Leading zeros = Sets either “Leading Blanks” or “Leading Zeros” on the LCD. * Meter Factor = (Manual entry

Page 7 - Mounting & Installation

15 * FPV Mode = (Auto or fixed). Use “Auto” to calculate FPV based on the configurations of the instrument. Use “Fixed” when using fixed factor measu

Page 8

16 DOWNLOADING AND PRINTING DATA To download data follow the steps below: 1. Run the HVC Host software 2. Go to the “Data” column. 3. Sele

Page 9

17 Configuring for use with an IP modem 1. Select “Host Setup – Configure Host”. 2. Click the “Network” Port Selection and then click “OK”.

Page 10

18 3. Select “Host Setup – Master Directory”. 4. Click on the “New IP Addr” button.

Page 11 - HVC HOST Operating Software

19 5. Enter the IP address, Port Number and choose a Name/Location for the installation. In the COM Selection drop-down box, click on “Select 4 –

Page 12

2 325 IS Series HVC User’s Manual & Field Installation Guide Proprietary Notice The contents of this manual are proprietary to Heath Consultan

Page 13 - Configure 1 Screen

20 8. Double-click the IP modem’s site name or single click the site name and then click “OK”. Editing is also available with this screen if neede

Page 14

21 10. Once connected, the Host screen will indicate the connected IP address in yellow at the bottom of the window. 11. Select “Security – Lo

Page 15

22 12. To illustrate remote IP modem communication, select “Display – Display 1 Volume Report”. 13. The Volume Report window will appear after t

Page 16

23 14. Remote HVC IP modem communications are available for use using the HVC Host. When finished, exit remote IP modem communications by selecti

Page 17

24 HVC Specifications Functionality Profiler Data Recording: Circular log; 130 days/hourly; Time/Corrected/Uncorrected/Ave Pressure/ Ave Gas Tempe

Page 18

25 Performance Accuracy: +/- 0.5% of reading inclusive of linearity, hysteresis, repeatability, long term drift & temperature Temperature: -40°

Page 19

26 HVC Troubleshooting The following may serve as a quick troubleshooting guide if you encounter problems in operating the HVC: Symptom Diagnosis W

Page 20

27 Symptom Diagnosis Not responding to temperature  Confirm temperature mode is set to AUTO  Check connections of temperature probe wires. 

Page 21

28 Annual Checks NOTE: Heath Consultants recommends annual checks on the HVC. 1. Verify calibration and recalibrate if required. 2. Verify pro

Page 22

29 3. Lightly push down on the center retainer clip and use a small, thin bladed screwdriver to gently pry the latches on the retainer clip free fr

Page 23

3 Table of Contents 325 IS Series ...

Page 24 - HVC Specifications

30 Replace the CR2032 coin cell back-up battery per the following: Warning – make sure the main battery voltage is at least 1.2 Vdc! 1. Locate

Page 25

31 Spare Parts & Accessories Pressure Transducer The HVC may be equipped with a wide variety of ranges, most of which are available in either

Page 26 - HVC Troubleshooting

32 Service Information: Warranties and Warranty Repair The HVC is warranted to be free from defects in material and workmanship for four (4) years

Page 27

33 Configuration Worksheet Complete this worksheet prior to leaving the meter shop to facilitate field configuration and documentation. Always reme

Page 28 - Annual Checks NOTE:

34 Configuration Item Value Pressure Mode: Temperature Mode: Fpv Mode: High Pressure Alarm Mode: Trip Point: Low Pressure Alarm Mode: Trip Point:

Page 29

35 Modem Configuration Value Remote Modem Baud Rate: Parity: Sandia ID: MODBUS Address : MODBUS Mode : Alarm Host Number: Modem Init String:

Page 30

36 Technical Support 1-800-HEATHUS (1-800-432-8487) Heath Consultants Factory Service Center 9030 Monroe Road Houston, Texas 77061 Phone: (713

Page 31

4 Heath Volume Corrector (HVC) Overview The HVC 325 is a microprocessor based, self-contained system designed for the purpose of performing ideal gas

Page 32 - Obtaining Service

5 Figure 1: LCD Display List: Corrected Volume (default after 4 minutes)/ Uncorrected Volume/ Correction Factor/ Gas Pressure/ Gas Temp/ Main

Page 33 - Configuration Worksheet

6 Figure 2: Inside configuration. Refer to drawing MTM-308-1 for field wiring requirements for external power and modem connections to main

Page 34

7 Mounting & Installation Equipment Required • Lap Top Computer (Using Win XP, Win Vista or Win 7) • Communications Cable • Test Gauge, Dead W

Page 35

8 Pressure Connection Connect the pressure (or gas) supply to the 1/4” NPT female connector located on the back of the HVC 325 housing. After piping

Page 36 - 1-800-HEATHUS

9 HVC 325 units are shipped from the factory, powered up and ready to install (Unless otherwise specified). The HVC 325 incorporates an on bo