Users Manual
Natural Gas (Methane)
ODORATOR
®
Vue de la page 0
1 2 3 4 5 6 ... 30 31

Résumé du contenu

Page 1 - ODORATOR

User’s ManualNatural Gas (Methane)ODORATOR®

Page 2 - PROPRIETARY NOTICE

Operation1OPERATION:This Chapter discusses the proper steps to safely operate the ODORATOR. Also included are procedures for periodic testing and iden

Page 3

Operation2. Connect the sample hose to the gas supply outlet valve and to the ODORATOR inlet port (1).3. Open the gas supply outlet valve and the OD

Page 4

Operation12. If the exhaust does not have a readily detectable odor repeat step 11. If the exhaust does have a readily detectable odor, push and hol

Page 5 - INTRODUCTION

Operation41. Gas Inlet 6. Calibration Sticker 2. Power Switch 7. Flow Metering Valve3. Power Indic

Page 6

Operation5Periodic Test:1. Every thirty (30) days the ODORATOR should be operated with the power switch on and while not hooked up to a gas supply.2.

Page 7 - WARNINGS AND CAUTION

Maintenance6Troubleshooting ChartMAINTENANCE:“LO BATT” appears on LCD.Weak batteries. Replace batteries.Motor and LCD will not turn on.RMASpeed Indica

Page 8

Maintenance7Parts ListThe following list species ODORATOR parts and accessories that are available from the factory or regional ofce. 07156

Page 9 - TABLE OF CONTENTS

Appendix A8ActionResults Operator NameTest Date Periodic Test Record

Page 10 - Chapter I

Appendix AActionResults Operator NameTest Date Periodic Test Record9

Page 11

Appendix B10Appendix BODORATOR Correction Chart for MethaneThis chart assumes the ODORATOR has been properly zeroed and allowed to run for at least on

Page 12

PROPRIETARY NOTICEThe contents of this instruction manual are proprietary to the Manufacturing Division of Heath Consultants Incorporated. Reproducti

Page 13 - Side View

Appendix C11Appendix CODORATOR Use at ElevationThe ODORATOR works by allowing a metered amount of sample gas to mix with a xed amount of air and the

Page 14 - Chapter II

Appendix C12**Note** The elevation correction chart supports new style Meth-ane ODORATORS only. Instruments manufactured before July 1997, that have

Page 15 - Chapter III

Appendix C13Elevation Corrections for the Methane ODORATORThe methane ODORATOR mixes air with natural gas to allow the user to determine the percent g

Page 16

Appendix CThe reading as a percentage between the adjacent chart readings can be used to determine the actual value using the same percentag

Page 17 - Periodic Test Record

Appendix CTherefore the actual value will be 30% of the difference in the chart higher actual from the chart lower actual. Again, the lower value will

Page 18

Appendix C16Elevation Change Correction ChartInstructions for correction on page 13Down 5,000’Down 4,000’Down 3,000’Down2,000’Down 1,000’Up 1,000’

Page 19 - Appendix B

Service17SERVICE INFORMATION:Warranties and Warranty RepairAll instruments and products manufactured by Heath Consultants Incorporated are warranted

Page 20 - ODORATOR Use at Elevation

Service18SERVICE INFORMATION:Return Procedure (RMA):The following steps will expedite the repair of your instrument:1. Contact Heath Factory Service

Page 21

Service19SALES, CUSTOMER SERVICE, AND INSTRUMENT REPAIR National Toll Free # 1-800-HEATH-US (1-800-432-8487)REGIONAL SALES, CUSTOMER SERVICE, AND INST

Page 22

Service20NOTES

Page 23

ODORATOR®User’s ManualHeath Consultants IncorporatedHouston, TX713/844-1300 Fax: 713/844-13091-800-HEATH-USwww.heathus.comHeath...Safety, Leadershi

Page 24

Service21NOTES

Page 25

Heath...Safety, Leadership, Innovation, PerformanceThen, Now and TomorrowHeath Consultants IncorporatedHouston, TX713-844-1300Fax: 713-844-13091-800-

Page 27

iNatural gas (methane) to be tested enters the ODORATOR through the barbed tting at the gas supply inlet port. Internally, the gas passes through an

Page 28

iiWhen the ODORATOR is turned on, the user might momentarily notice the letter “L” on the LCD when the READ switch is depressed and held down. I

Page 29

WARNINGS AND CAUTIONPRIOR TO USE, OPERATOR SHOULD READ ALL PRECAUTIONS, INSTRUCTIONS FOR OPERATION, AND MAINTENANCE REQUIREMENTS CONTAINED IN PRODUCT

Page 30

ivANY TIME GAS IS BEING PASSED THROUGH THE ODORATOR THE POWER SWITCH MUST BE TURNED ON. THIS WILL DILUTE THE GAS AT THE EXHAUST PORT AND PREVENT POCKE

Page 31 - 1-800-HEATH-US