AQUA-SCOPE
User Manual
®
Vue de la page 0
1 2 3 4 5 6 ... 38 39

Résumé du contenu

Page 1 - AQUA-SCOPE

AQUA-SCOPEUser Manual®

Page 2 - Revision B

The push button “LISTEN” control switch should only be depressed after the ground microphone has been rmly placed on a solid surface and one to two s

Page 3

Figure 4 illustrates the Ground Microphone with the Ground Microphone Handle. The shock insulator minimizes sound coupling through the handle. The foa

Page 4 - INTRODUCTION

C. Direct Contact Microphone (Part No. 2916428)(Figure 5)1. General Specications: Construction: Cold rolled steel case. Stainless steel

Page 5 - TABLE OF CONTENTS

D. Headphones (part No. 2911352)(Figure 6)1. General Specications: Weight: Approximately 0.94 Lbs (425 Grams) Impedance: 600 Ohms D

Page 6

E. Meter Module (part No. 2923754)(Figure 7) 1. General Specications: Weight: Approximately 1.2 Lbs. (545 Grams) Size: Same as Amplier M

Page 7 - CHAPTER ONE

Figure 7 illustrates the Meter Readout Module, an accessory item with AQUA-SCOPE® . The charger plug/jack system differs from the plugs and jacks used

Page 8

G. Plunger Bar(Figure 9)1. General Specications: Weight: 13 Lbs. (5.9 Kg) Length: 62” (assembled) Bar Length: 40” Bar: Standard Steel Temp

Page 9

III. PRINCIPLES OF SOUND: A. Engineering ReferencesThis section will cover the basic physics of sound. Section B will attempt to relate a few of the

Page 10

The Transmission Velocity of Sound in an extended solid is given by: VELOCITY Longitudinal = Where: EB = The Bulk Modulus (Rigidity) of the Solid

Page 11

The Velocity of Sound is given by:Where: V = Velocity γ = the ratio of the specic heat at constant pressure to the specic heat at const

Page 12

Proprietary NoticeThe contents of this manual are proprietary to Heath Consultants Incorporated. Reproduction of this manual, in whole or in part, is

Page 13

Absorption of sound by materials is a science in itself. Terms often stated by acoustical wall manufacturers are seal and absorption loss. Seal refers

Page 14

The frequency and velocity of the sound induced on the pipe by a leak will be a function of pipe size, thickness, material and boundary co

Page 15

IV. AQUA-SCOPE USER’S GUIDE: A. ApplicationThe pinpointing of unknown water leakage can be accomplished by the use of a combination of components, w

Page 16

(Figure 10)As you can see from Figure 10, in preliminary detection the Direct Contact Microphone is connected with the Amplier Module and the Headset

Page 17 - CHAPTER TWO

SOUND LEVEL INTENSITY AT DIFFERENT TEST POINTS(Figure 11)Example of a Preliminary Detection (Figure 12): After opening valve boxes on the main at 1,

Page 18

At point 7 there is no curb valve present nor is there any accessible contact point on the service to the house. Therefore, a direct contact inside th

Page 19

SOUND LEVEL INTENSITY AT DIFFERENT TEST POINTS(Figure 13)For the pinpointing of the leak, the Ground Microphone will be placed as exactly as possible

Page 20

Inuence of the Leak Noise (Material of the Lines):You should know the material of the line being tested as the sound transmission of leak sounds vary

Page 21

D. Exercises with the Direct Contact/Ground Microphone Initially it is necessary to become acquainted with the background noise of the instrum

Page 22 - CHAPTER THREE

If you are inspecting an intersection with several valves, these results may be predicted:1. Using the Direct Contact Microphone at point 3, a leakin

Page 23

AQUA-SCOPE®User ManualHeath Consultants IncorporatedHouston, TX713-844-1300 Fax: 713-844-13091-800-HEATH-USwww.heathus.comHeath...Safety, Leadership,

Page 24

This gives two simultaneous equations: IA XA - IB XB = O XA + XB = X O -IB X 1 IBX XA = ———— =

Page 25

By the numerical technique the distance from test point A to the leak is: XA = ( .9 ) x 70 Yards = 52.5 Yards .9 + .3 Similarly: XB =

Page 26

F. Practical ExamplesTest probe measurement at valve 1 is .40 units; at valve 2, .90 units; at valve 3, .10 units, and at hydrant 4, zero units. This

Page 27

(Figure 18)The noise of the leak should be checked with the Direct Contact Microphone at hydrant 4 and at valve 6. Pinpointing with the Ground Microph

Page 28

(Figure 20)Leakage on Asbestos-Cement and Plastic PipeThe very poor transmission of sound on this material will make other methods for detection neces

Page 29

1. Nitrous Oxide with Infrared Detection: One of the advantages of nitrous oxide is that it is water soluble and the line does not have to be dewater

Page 30 - 1 1

33V. SERVICE INFORMATION:A. Warranties and Warranty RepairAll instruments and products manufactured by the Heath Consultants Incorporated are warran

Page 31

There are no other warranties expressed, implied or written except as listed above.The following suggestions will expedite the repair of your instrume

Page 32

CUSTOMER ASSISTANCE, MANUFACTURING AND SERVICE LOCATIONSCORPORATE HEADQUARTERSHeath Consultants Incorporated9030 Monroe RoadHouston, Texas 77061Phone:

Page 33

Heath...Safety, Leadership, Innovation, PerformanceThen, Now and TomorrowHeath Consultants IncorporatedHouston, TX713-844-1300Fax: 713-844-13091-800-

Page 34

INTRODUCTIONEconomy and hygiene demand the most expedient way to locate and repair water pipeline damage. More extensive water leaks can also result i

Page 35

INTRODUCTION...1FUNCTION ...

Page 36 - CHAPTER FOUR

CHAPTER THREEIV. AQUA-SCOPE OPERATION:A. Application ... 19B. Leakage Detection with t

Page 37

I. AQUA-SCOPE SYSTEM, COMPLETE:(Figure 1)AQUA-SCOPE Basic System (part No. 2903768) 1. Direct Contact 5. Ground Microphone Microphone w/ext

Page 38

II. AQUA-SCOPE SYSTEM, COMPLETE W/ OPTIONAL ACCESSORIES: (Figure 2)AQUA-SCOPE System with Optional Accessories8. Meter Module w/ Battery 12. Go

Page 39 - 1-800-HEATH-US

A. Amplier Module (Part No. 2916426) (Figure 3)1. General Specications: Weight: 1.37 lbs. (620 grams) including batteries. Size: 5” deep x 3.